EasyManua.ls Logo

Siemens SINAMICS S120 - Page 93

Siemens SINAMICS S120
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
5.4 Creating a project offline in Startdrive
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
91
Procedure
1. Select the motor in the device view and open the Inspector window.
2. In the Inspector window, select the "Motor details > Rating plate values" menu.
In the screen form, the following setting options are displayed:
Figure 5-24 Motor details rating plate values
3. To perform the basic parameter assignment for the motor, click the icon next to the
"Basic parameter assignment" entry.
The function view of the drive axis is opened:
Make the required settings here (see chapter "Basic parameter assignment (Page 115)").
4. In the Inspector window, select the menu "Motor details > Rating plate values" again.
5. Make the settings in the white fields.
The gray fields are refreshed automatically in accordance with your settings.
6. In the Inspector window, select the "Motor details > Motor brake" menu.
The current configuration of the motor holding brake is displayed in the screen form.
Figure 5-25 Motor details motor brake

Table of Contents