Startdrive commissioning tool
3.2 User interface - parameterization
38 Getting Started, 12/2018, 6SL3097-5AG30-0BP0
Structure of the parameter view
The following figure shows the structure of the parameter view:
Secondary navigation: Limits the parameter display to the required parameter group. Applies to S120, S150, G150
and G130.
Exception: MV drive units do not use secondary navigation in the parameter view.
Drop-down list to restrict the parameter views:
Display standard parameters
Display extended parameters
Display service parameters
Parameter number
Button for comparing the parameters of the drive object to another parameter set.
In offline mode, the parameters are compared to the factory settings by default.
In online mode, the parameters are compared to the offline settings by default.
The comparison can also be disabled again.
Button for starting a CSV export:
Save all of the displayed parameters to a CSV file.
Save all of the parameters of the drive object to a CSV file.
Button to retentively save the parameters (Copy RAM to ROM).
Button to restore the factory settings.
Button for displaying open BICO interconnections of all of the drive objects in the offline project.
Parameter name
Value of the parameter
Unit
Data set: Indicates the data set (MDS, DDS, etc.) to which the parameter belongs.
Minimum value
Maximum value
Figure 3-7 Parameter list