EasyManua.ls Logo

Siemens SINAMICS S120 - Page 75

Siemens SINAMICS S120
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
5.4 Creating a project offline in Startdrive
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
73
Procedure
You can add an infeed via the hardware catalog.
1. Open the "Line Modules" entry in the hardware catalog.
Active Line Modules, Basic Line Modules and Smart Line Modules can be selected.
2. Select the unspecified infeed in the hardware catalog.
Figure 5-6 Selecting an infeed
3. Drag the unspecified infeed to the device view.
Figure 5-7 Infeed inserted
Generally, the DRIVE-CLiQ connection is automatically established. The unspecified
infeed must now be specified in more detail.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals