Commissioning
8.3 Commissioning using the BOP20 operator panel
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
273
8.3
Commissioning using the BOP20 operator panel
8.3.1
Preconditions
Fundamentals of SINAMICS
If you are not yet familiar with SINAMICS basics (parameters, drive objects, BICO
technology, etc.), please read Chapter "Basic information (Page 349)" before starting
commissioning.
BOP20 operator panel
If you are not yet familiar with the BOP20 operator panel, please read Chapter
"Parameterizing using the BOP20 (Basic Operator Panel 20) (Page 368)" before starting
commissioning.
Parameter notation
Expressed in full, a parameter consists of
the drive object + parameter number + index, with the following notation
(oo)pxxxxx[ii]
for indexed parameters
(oo)pxxxxx
for non
-indexed parameters
To make these easier to read, in this chapter the drive object specification has been omitted
from all parameters belonging to the "Drive control" drive object (= drive object 2).
For example, the specification p50076[1] refers to parameter (2)p50076[1] (= drive object 2,
parameter 50076, index 1).

Table of Contents

Other manuals for Siemens SINAMICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS Series and is the answer not in the manual?

Siemens SINAMICS Series Specifications

General IconGeneral
Product LineSINAMICS
Cooling MethodAir-cooled, Liquid-cooled
Voltage Range200 V to 690 V
Power Range0.12kW - 250kW
Communication InterfacesPROFINET, PROFIBUS, Ethernet
Control ModesVector control, V/f control
Protection ClassIP20
TypeVariable Frequency Drives (VFD)