EasyManuals Logo

Siemens SINAMICS Series User Manual

Siemens SINAMICS Series
758 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #281 background imageLoading...
Page #281 background image
Commissioning
8.3 Commissioning using the BOP20 operator panel
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
279
〈7.2〉Torque limits
p50180[D]
Torque limit 1 in torque direction I
(as % of rated motor torque)
p50181[D]
Torque limit 1 in torque direction II
(as % of rated motor torque)
〈7.3〉Ramp-function generator
p50303[D]
Ramp-up time 1 (in seconds)
p50304[D]
Ramp-down time 1 (in seconds)
p50305[D]
Initial rounding 1 (in seconds)
p50306[D]
Final rounding 1 (in seconds)
〈8〉Complete quick commissioning
Set p3900 = 3.
This triggers the calculation of the motor data (Ra, La, Lf) as well as the calculation of the
controller parameters resulting from the data that was entered in the previous steps.
p3900 is then reset to 0 and quick commissioning is ended, i.e. p0010 is reset to 0.
〈9〉Execute optimization runs
Perform the optimization runs one after the other:
p50051 = 23
Optimization of the armature current control for induction load
p50051 = 24
Optimization of the field current control
p50051 = 25
Optimization of the armature current control
p50051 = 26
Optimization of the speed control
p50051 = 27
Optimization of the EMF control (incl. field characteristic recording)
p50051 = 28
Recording of the friction characteristic
p50051 = 29
Optimization of the speed control for drives with a mechanical system
capable of oscillation
For further details, see Chapter "Drive optimization (Page 336)".
If an optimization run is not carried out, the motor control uses the motor characteristic
values calculated from the rating plate data rather than the measured values.

Table of Contents

Other manuals for Siemens SINAMICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS Series and is the answer not in the manual?

Siemens SINAMICS Series Specifications

General IconGeneral
Product LineSINAMICS
Cooling MethodAir-cooled, Liquid-cooled
Voltage Range200 V to 690 V
Power Range0.12kW - 250kW
Communication InterfacesPROFINET, PROFIBUS, Ethernet
Control ModesVector control, V/f control
Protection ClassIP20
TypeVariable Frequency Drives (VFD)