EasyManuals Logo

Siemens SINAMICS Series User Manual

Siemens SINAMICS Series
758 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #610 background imageLoading...
Page #610 background image
Descriptions of functions
10.28 Connecting units in parallel and in series
SINAMICS DCM DC Converter
608 Operating Instructions, 12/2018, A5E34763375A
Table 10- 71 6-pulse parallel connection n+m operation
Parameter
Master
Substitute master
Slave
p51799 Operating principle 0 The same as at the
master
The same as at the
master
p51800 Position in the topology 11 (Master) 13 (Substitute master) 12 (Slave)
p51801
Number of send data
Any
Any
Any
p51802 Minimum number of nodes n The same as at the
master
The same as at the
master
p51812 Total number of nodes n+m The same as at the
master
The same as at the
master
p51803 n+m mode 1 (only armature)
2 (armature + field)
The same as at the
master
0
p51804[..]
Transmit data
Any
Any
Any
p51805
Bus terminator
0 or 1
1)
0 or 1
1)
0 or 1
1)
p51806
Station address
Unique address
Unique address
Unique address
p51807
Telegram failure time
0.1 s
0.1 s
0.1 s
p50082 Field operating mode ≠ 0 0 (if only armature)
≠ 0 (if armature + field)
0 (no field)
p50076[..] Reduction in rated unit DC
current
- The same as at the
master
The same as at the
master
p50078[..] Rated value for supply
voltage
- The same as at the
master
The same as at the
master
p50100 Rated motor current Rated motor
current/number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50110 Armature resistance Ra
2)
Actual armature
resistance × number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50111 Armature inductance La
2)
Actual armature
inductance × number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50114 Motor thermal time
constant
Motor thermal time
constant in s
The same as at the
master
The same as at the
master
p50140 Motor I
2
t monitoring,
response when starting
Application-specific The same as at the
master
The same as at the
master
p50115 to
p50139
Field characteristic - The same as at the
master
(only if n+ m operation for
armature + field)
The same as at the
master
p51591 La reduction factor
2)
- The same as at the
master
The same as at the
master
p50357 Threshold for interrupted
tachometer
Application-specific The same as at the
master
100% (tachometer
interruption monitoring
not active)
1)
= 1 at the two outermost units (= at the physical ends of the bus line)
= 0 on all of the other units
2)
The optimization run for current controller and precontrol (p50051 = 23 or 25) sets the correct values for these
parameters.

Table of Contents

Other manuals for Siemens SINAMICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS Series and is the answer not in the manual?

Siemens SINAMICS Series Specifications

General IconGeneral
Product LineSINAMICS
Cooling MethodAir-cooled, Liquid-cooled
Voltage Range200 V to 690 V
Power Range0.12kW - 250kW
Communication InterfacesPROFINET, PROFIBUS, Ethernet
Control ModesVector control, V/f control
Protection ClassIP20
TypeVariable Frequency Drives (VFD)

Related product manuals