Descriptions of functions
10.28 Connecting units in parallel and in series
SINAMICS DCM DC Converter
610 Operating Instructions, 12/2018, A5E34763375A
Figure 10-78 12-pulse parallel connection (2), block diagram
Note
If additional converters are connected in parallel to the master converter, then exactly the
same number of converters must also be connected in parallel with the slave converter.