10.38 Write and know-how protection
SINAMICS DCM DC Converter
682 Operating Instructions, 12/2018, A5E34763375A
2. If you want to save with protection, activate the "Know-how protection without copy
protection" or "Know-how protection with copy protection" option.
Figure 10-109 Activating load to file system know-how protection
The input fields are then active. Without copy protection, only the input fields for
password input are active. With copy protection, the two input fields for the serial number
are also active. Generally, the entries in the input fields are shown in encrypted form.
3. Enter the required password in the "New password" field and enter it again in the
"Confirm password" field.
4. Enter the serial number of the new memory card for which the data is intended.
If you have selected the "Know-how protection with copy protection" option, the input of
the Control Unit serial number is also obligatory.
5. In this case, also enter the serial number of the Control Unit in the appropriate input field.
6. Click "OK" to confirm the settings you made.
Result
The data of the subproject is stored in the required encryption in your file system. With the
aid of this encrypted data, an end user can install a new memory card or Control Unit for the
drive unit.

Table of Contents

Other manuals for Siemens SINAMICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS Series and is the answer not in the manual?

Siemens SINAMICS Series Specifications

General IconGeneral
Product LineSINAMICS
Cooling MethodAir-cooled, Liquid-cooled
Voltage Range200 V to 690 V
Power Range0.12kW - 250kW
Communication InterfacesPROFINET, PROFIBUS, Ethernet
Control ModesVector control, V/f control
Protection ClassIP20
TypeVariable Frequency Drives (VFD)

Related product manuals