Tables
12.1 List of statements
Fundamentals
436 Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
Name Meaning Value Description,
comment
Syntax m/s
3
Group
2
CFIN
Constant feed at internal radius only, not
at external radius
m 16
CFTCP Constant feed in tool-center- point (center-
point path)
m 16
CHAN Specify validity range for data Once per
channel
CHANDATA Set channel number for
channel data access
INT Only
permissible in
the initialization
module.
CHAR Data type: ASCII
character
0, ..., 255
CHECKSUM Forms the checksum over
a an array as a fixed-
length STRING
Max. length
32
Returns string
of 16 hex digits.
ERROR=
CHECKSUM
CHF
CHR
Chamfer;
value = length of chamfer
Chamfer;
value = width of chamfer
in direction of movement
(chamfer)
Real, w/o
signs
s
CHKDNO Check for unique D numbers
CIC Incremental approach of position
(coded position: incremental coordinate)
See CAC.
CIP Circular interpolation through intermediate
point
CIP X... Y... Z...
I1=... J1=... K1=...
m 1
CLEARM Reset one/several
markers for channel
coordination
INT,
1 - n
Does not
influence
machining in
own channel.
CLRINT Deselect interrupt: INT Parameter:
Interrupt
number
CMIRROR Mirror on a coordinate
axis
FRAME
COARSEA Motion end when "Exact stop coarse"
reached
COARSEA=... or
COARSEA[n]=...
m
COMPOF
1,6
Compressor OFF m 30
COMPON
6
Compressor ON m 30
COMPCURV Compressor ON: Polynomials with
constant curvature
m 30
COMPCAD Compressor ON: Optimized surface quality
CAD program
m 30