2 Functions
150
7SA522 Manual
C53000-G1176-C155-3
4007 >Dis.T.RecCh1L1 SP >Dis.Tele.Carrier RECEPTION Channel 1,L1
4008 >Dis.T.RecCh1L2 SP >Dis.Tele.Carrier RECEPTION Channel 1,L2
4009 >Dis.T.RecCh1L3 SP >Dis.Tele.Carrier RECEPTION Channel 1,L3
4010 >Dis.T.Rec.Ch2 SP >Dis.Tele. Carrier RECEPTION Channel 2
4030 >Dis.T.UB ub 1 SP >Dis.Tele. Unblocking: UNBLOCK Channel 1
4031 >Dis.T.UB bl 1 SP >Dis.Tele. Unblocking: BLOCK Channel 1
4032 >Dis.T.UB ub1L1 SP >Dis.Tele. Unblocking: UNBLOCK Ch. 1, L1
4033 >Dis.T.UB ub1L2 SP >Dis.Tele. Unblocking: UNBLOCK Ch. 1, L2
4034 >Dis.T.UB ub1L3 SP >Dis.Tele. Unblocking: UNBLOCK Ch. 1, L3
4035 >Dis.T.UB ub 2 SP >Dis.Tele. Unblocking: UNBLOCK Channel 2
4036 >Dis.T.UB bl 2 SP >Dis.Tele. Unblocking: BLOCK Channel 2
4040 >Dis.T.BlkEcho SP >Dis.Tele. BLOCK Echo Signal
4050 Dis.T.on/off BI IntSP Dis. Teleprotection ON/OFF via BI
4052 Dis.Telep. OFF OUT Dis. Teleprotection is switched OFF
4054 Dis.T.Carr.rec. OUT Dis. Telep. Carrier signal received
4055 Dis.T.Carr.Fail OUT Dis. Telep. Carrier CHANNEL FAILURE
4056 Dis.T.SEND OUT Dis. Telep. Carrier SEND signal
4057 Dis.T.SEND L1 OUT Dis. Telep. Carrier SEND signal, L1
4058 Dis.T.SEND L2 OUT Dis. Telep. Carrier SEND signal, L2
4059 Dis.T.SEND L3 OUT Dis. Telep. Carrier SEND signal, L3
4060 DisJumpBlocking OUT Dis.Tele.Blocking: Send signal with jump
4068 Dis.T.Trans.Blk OUT Dis. Telep. Transient Blocking
4070 Dis.T.BL STOP OUT Dis. Tele.Blocking: carrier STOP signal
4080 Dis.T.UB Fail1 OUT Dis. Tele.Unblocking: FAILURE Channel 1
4081 Dis.T.UB Fail2 OUT Dis. Tele.Unblocking: FAILURE Channel 2
4082 Dis.T.BL STOPL1 OUT DisTel Blocking: carrier STOP signal, L1
4083 Dis.T.BL STOPL2 OUT DisTel Blocking: carrier STOP signal, L2
4084 Dis.T.BL STOPL3 OUT DisTel Blocking: carrier STOP signal, L3
4085 Dis.T.RecL1Dev1 OUT Dis.Tele.Carrier RECEPTION, L1, Device1
4086 Dis.T.RecL2Dev1 OUT Dis.Tele.Carrier RECEPTION, L2, Device1
4087 Dis.T.RecL3Dev1 OUT Dis.Tele.Carrier RECEPTION, L3, Device1
4088 Dis.T.RecL1Dev2 OUT Dis.Tele.Carrier RECEPTION, L1, Device2
4089 Dis.T.RecL2Dev2 OUT Dis.Tele.Carrier RECEPTION, L2, Device2
4090 Dis.T.RecL3Dev2 OUT Dis.Tele.Carrier RECEPTION, L3, Device2
4091 Dis.T.RecL1Dev3 OUT Dis.Tele.Carrier RECEPTION, L1, Device3
4092 Dis.T.RecL2Dev3 OUT Dis.Tele.Carrier RECEPTION, L2, Device3
4093 Dis.T.RecL3Dev3 OUT Dis.Tele.Carrier RECEPTION, L3, Device3
No. Information Type of In-
formation
Comments

Table of Contents

Other manuals for Siemens siprotec 7SA522

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SA522 and is the answer not in the manual?

Siemens siprotec 7SA522 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SA522
CategoryProtection Device
LanguageEnglish

Related product manuals