1.3 Characteristics
25
7SA522 Manual
C53000-G1176-C155-3
1.3 Characteristics
General Features Powerful 32-bit microprocessor system
Complete digital processing of measured values and control, from the sampling of
the analog input values up to the closing and tripping commands to the circuit
breakers
Complete galvanic and reliable separation between internal processing circuits
from the measurement, control, and power supply circuits by analog input transduc-
ers, binary inputs and outputs and the DC/DC or AC/DC converters
Complete scope of functions which are normally required for the protection of a line
feeder
Digital protection data transmission, may be used for teleprotection with permanent
monitoring of disturbance, fault or transfer time deviations in the communication
network with automatic runtime re-adjustment
Distance protection system realizable for 3 ends
Simple device operation using the integrated operator panel or a connected person-
al computer with operator guidance
Storage of fault indications as well as instantaneous values for fault recording
Distance Protection Protection for all types of faults in systems with earthed, compensated or isolated
starpoint
Selectable polygonal tripping characteristic or MHO-circle characteristic;
Reliable differentiation between load and fault conditions also on long, high-loaded
lines
High sensitivity in the case of a weakly loaded system, extreme stability against
load jumps and power swings
Optimum adaption to the line parameters by means of the tripping characteristic
with diverse configuration parameters and “load trapezoid” (elimination of the pos-
sible load impedances);
Six measuring systems for each distance zone
Six distance zones, selectable as forward, reverse or non-directional reaching, one
may be used as an overreach zone
Nine time stages for the distance zones
Direction determination (with polygon) or polarisation (with MHO-circle) is done with
unfaulted loop (quadrature) voltages and voltage memory, thereby achieving unlim-
ited directional sensitivity, and not affected by capacitive voltage transformer tran-
sients
Suitable for lines with series compensation
Insensitive to current transformer saturation
Compensation against the influence of a parallel line
Shortest tripping time is approx. 17 ms (for f
N
= 50 Hz) or 15 ms (for f
N
= 60 Hz)
Phase segregated tripping (in conjunction with single-pole or single- and three-pole
auto-reclosure)
Non-delayed tripping following switch onto fault

Table of Contents

Other manuals for Siemens siprotec 7SA522

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SA522 and is the answer not in the manual?

Siemens siprotec 7SA522 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SA522
CategoryProtection Device
LanguageEnglish

Related product manuals