A.7 Settings
541
7SA522 Manual
C53000-G1176-C155-3
3458 1.AR: Tdead EV. Autoreclosure 0.01 .. 1800.00 sec 1.20 sec Dead time after evolving fault
3459 1.AR: CB? CLOSE Autoreclosure YES
NO
NO CB ready interrogation before re-
closing
3460 1.AR SynRequest Autoreclosure YES
NO
NO Request for synchro-check after
3pole AR
3461 2.AR: START Autoreclosure YES
NO
NO AR start allowed in this cycle
3462 2.AR: T-ACTION Autoreclosure 0.01 .. 300.00 sec; 0.20 sec Action time
3464 2.AR Tdead 1Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 1phase faults
3465 2.AR Tdead 2Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 2phase faults
3466 2.AR Tdead 3Flt Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3phase faults
3467 2.AR Tdead1Trip Autoreclosure 0.01 .. 1800.00 sec; ∞∞sec Dead time after 1pole trip
3468 2.AR Tdead3Trip Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3pole trip
3469 2.AR: Tdead EV. Autoreclosure 0.01 .. 1800.00 sec 1.20 sec Dead time after evolving fault
3470 2.AR: CB? CLOSE Autoreclosure YES
NO
NO CB ready interrogation before re-
closing
3471 2.AR SynRequest Autoreclosure YES
NO
NO Request for synchro-check after
3pole AR
3472 3.AR: START Autoreclosure YES
NO
NO AR start allowed in this cycle
3473 3.AR: T-ACTION Autoreclosure 0.01 .. 300.00 sec; 0.20 sec Action time
3475 3.AR Tdead 1Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 1phase faults
3476 3.AR Tdead 2Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 2phase faults
3477 3.AR Tdead 3Flt Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3phase faults
3478 3.AR Tdead1Trip Autoreclosure 0.01 .. 1800.00 sec; ∞∞sec Dead time after 1pole trip
3479 3.AR Tdead3Trip Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3pole trip
3480 3.AR: Tdead EV. Autoreclosure 0.01 .. 1800.00 sec 1.20 sec Dead time after evolving fault
3481 3.AR: CB? CLOSE Autoreclosure YES
NO
NO CB ready interrogation before re-
closing
3482 3.AR SynRequest Autoreclosure YES
NO
NO Request for synchro-check after
3pole AR
3483 4.AR: START Autoreclosure YES
NO
NO AR start allowed in this cycle
3484 4.AR: T-ACTION Autoreclosure 0.01 .. 300.00 sec; 0.20 sec Action time
3486 4.AR Tdead 1Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 1phase faults
3487 4.AR Tdead 2Flt Autoreclosure 0.01 .. 1800.00 sec; 1.20 sec Dead time after 2phase faults
3488 4.AR Tdead 3Flt Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3phase faults
3489 4.AR Tdead1Trip Autoreclosure 0.01 .. 1800.00 sec; ∞∞sec Dead time after 1pole trip
3490 4.AR Tdead3Trip Autoreclosure 0.01 .. 1800.00 sec; 0.50 sec Dead time after 3pole trip
3491 4.AR: Tdead EV. Autoreclosure 0.01 .. 1800.00 sec 1.20 sec Dead time after evolving fault
3492 4.AR: CB? CLOSE Autoreclosure YES
NO
NO CB ready interrogation before re-
closing
3493 4.AR SynRequest Autoreclosure YES
NO
NO Request for synchro-check after
3pole AR
3501 FCT Synchronism Sync. Check ON
OFF
ON:w/o CloseCmd
ON Synchronism and Voltage Check
function
3502 Dead Volt. Thr. Sync. Check 1 .. 60 V 5 V Voltage threshold dead line / bus
3503 Live Volt. Thr. Sync. Check 20 .. 125 V 90 V Voltage threshold live line / bus
3504 Umax Sync. Check 20 .. 140 V 110 V Maximum permissible voltage
3507 T-SYN. DURATION Sync. Check 0.01 .. 600.00 sec; 1.00 sec Maximum duration of synchronism-
check
3508 T SYNC-STAB Sync. Check 0.00 .. 30.00 sec 0.00 sec Synchronous condition stability
timer
3509 SyncCB Sync. Check None
Breaker
Disc.Swit.
EarthSwit
Q2 Op/Cl
Q9 Op/Cl
Fan ON/OFF
None Synchronizable circuit breaker