A.8 Information List
557
7SA522 Manual
C53000-G1176-C155-3
1336 E/F phase selector L1 selected
(E/F L1 selec.)
Earth Fault O/C OUT * ON
OFF
* LED BO
1337 E/F phase selector L2 selected
(E/F L2 selec.)
Earth Fault O/C OUT * ON
OFF
* LED BO
1338 E/F phase selector L3 selected
(E/F L3 selec.)
Earth Fault O/C OUT * ON
OFF
* LED BO
1345 Earth fault protection PICKED
UP (EF Pickup)
Earth Fault O/C OUT * off m LED BO 166 45 2 Yes
1354 E/F 3I0>>> PICKED UP (EF
3I0>>>Pickup)
Earth Fault O/C OUT * ON * LED BO
1355 E/F 3I0>> PICKED UP (EF 3I0>>
Pickup)
Earth Fault O/C OUT * ON * LED BO
1356 E/F 3I0> PICKED UP (EF 3I0>
Pickup)
Earth Fault O/C OUT * ON * LED BO
1357 E/F 3I0p PICKED UP (EF 3I0p
Pickup)
Earth Fault O/C OUT * ON * LED BO
1358 E/F picked up FORWARD (EF
forward)
Earth Fault O/C OUT * ON * LED BO 166 58 2 No
1359 E/F picked up REVERSE (EF re-
verse)
Earth Fault O/C OUT * ON * LED BO 166 59 2 No
1361 E/F General TRIP command (EF
Trip)
Earth Fault O/C OUT * * * LED BO 166 61 2 No
1362 Earth fault protection: Trip 1pole
L1 (E/F Trip L1)
Earth Fault O/C OUT * ON m LED BO 166 62 2 Yes
1363 Earth fault protection: Trip 1pole
L2 (E/F Trip L2)
Earth Fault O/C OUT * ON m LED BO 166 63 2 Yes
1364 Earth fault protection: Trip 1pole
L3 (E/F Trip L3)
Earth Fault O/C OUT * ON m LED BO 166 64 2 Yes
1365 Earth fault protection: Trip 3pole
(E/F Trip 3p)
Earth Fault O/C OUT * ON m LED BO 166 65 2 Yes
1366 E/F 3I0>>> TRIP (EF 3I0>>>
TRIP)
Earth Fault O/C OUT * ON * LED BO 166 66 2 No
1367 E/F 3I0>> TRIP (EF 3I0>> TRIP) Earth Fault O/C OUT * ON * LED BO 166 67 2 No
1368 E/F 3I0> TRIP (EF 3I0> TRIP) Earth Fault O/C OUT * ON * LED BO 166 68 2 No
1369 E/F 3I0p TRIP (EF 3I0p TRIP) Earth Fault O/C OUT * ON * LED BO 166 69 2 No
1370 E/F Inrush picked up (EF Inrush-
PU)
Earth Fault O/C OUT * ON
OFF
* LED BO 166 70 2 No
1371 E/F Telep. Carrier SEND signal,
Phase L1 (EF Tele SEND L1)
Teleprot. E/F OUT on on * LED BO 166 71 1 No
1372 E/F Telep. Carrier SEND signal,
Phase L2 (EF Tele SEND L2)
Teleprot. E/F OUT on on * LED BO 166 72 1 No
1373 E/F Telep. Carrier SEND signal,
Phase L3 (EF Tele SEND L3)
Teleprot. E/F OUT on on * LED BO 166 73 1 No
1374 E/F Telep. Block: carrier STOP
signal L1 (EF Tele STOP L1)
Teleprot. E/F OUT * on * LED BO 166 74 1 No
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Inputs
Function Key
Relay
Chatter suppression
Type
Information Number
Data Unit
General Interrogation