A Appendix
572
7SA522 Manual
C53000-G1176-C155-3
3823 DisTRIP 3phase in Z1 with
single-ph Flt. (DisTRIP3p. Z1sf)
Dis. General OUT * * * LED BO 28 224 2 No
3824 DisTRIP 3phase in Z1 with multi-
ph Flt. (DisTRIP3p. Z1mf)
Dis. General OUT * * * LED BO 28 225 2 No
3825 DisTRIP 3phase in Z1B with
single-ph Flt (DisTRIP3p.Z1Bsf)
Dis. General OUT * * * LED BO 28 244 2 No
3826 DisTRIP 3phase in Z1B with
multi-ph Flt. (DisTRIP3p Z1Bmf)
Dis. General OUT * * * LED BO 28 245 2 No
3850 DisTRIP Z1B with Teleprotection
scheme (DisTRIP Z1B Tel)
Dis. General OUT * * * LED BO 28 251 2 No
4001 >Distance Teleprotection ON
(>Dis.Telep. ON)
Teleprot. Dist. SP * * * LED BI BO
4002 >Distance Teleprotection OFF
(>Dis.Telep.OFF)
Teleprot. Dist. SP * * * LED BI BO
4003 >Distance Teleprotection BLOCK
(>Dis.Telep. Blk)
Teleprot. Dist. SP ON
OFF
ON
OFF
* LED BI BO 29 3 1 Yes
4005 >Dist. teleprotection: Carrier
faulty (>Dis.RecFail)
Teleprot. Dist. SP on
off
**LEDBIBO
4006 >Dis.Tele. Carrier RECEPTION
Channel 1 (>DisTel Rec.Ch1)
Teleprot. Dist. SP on
off
on * LED BI BO 29 6 1 Yes
4007 >Dis.Tele.Carrier RECEPTION
Channel 1,L1 (>Dis.T.RecCh1L1)
Teleprot. Dist. SP on
off
on * LED BI BO 29 7 1 Yes
4008 >Dis.Tele.Carrier RECEPTION
Channel 1,L2 (>Dis.T.RecCh1L2)
Teleprot. Dist. SP on
off
on * LED BI BO 29 8 1 Yes
4009 >Dis.Tele.Carrier RECEPTION
Channel 1,L3 (>Dis.T.RecCh1L3)
Teleprot. Dist. SP on
off
on * LED BI BO 29 9 1 Yes
4010 >Dis.Tele. Carrier RECEPTION
Channel 2 (>Dis.T.Rec.Ch2)
Teleprot. Dist. SP on
off
on * LED BI BO 29 10 1 Yes
4030 >Dis.Tele. Unblocking:
UNBLOCK Channel 1 (>Dis.T.UB
ub 1)
Teleprot. Dist. SP on
off
on * LED BI BO 29 30 1 Yes
4031 >Dis.Tele. Unblocking: BLOCK
Channel 1 (>Dis.T.UB bl 1)
Teleprot. Dist. SP on
off
on * LED BI BO 29 31 1 Yes
4032 >Dis.Tele. Unblocking:
UNBLOCK Ch. 1, L1 (>Dis.T.UB
ub1L1)
Teleprot. Dist. SP on
off
on * LED BI BO 29 32 1 Yes
4033 >Dis.Tele. Unblocking:
UNBLOCK Ch. 1, L2 (>Dis.T.UB
ub1L2)
Teleprot. Dist. SP on
off
on * LED BI BO 29 33 1 Yes
4034 >Dis.Tele. Unblocking:
UNBLOCK Ch. 1, L3 (>Dis.T.UB
ub1L3)
Teleprot. Dist. SP on
off
on * LED BI BO 29 34 1 Yes
4035 >Dis.Tele. Unblocking:
UNBLOCK Channel 2 (>Dis.T.UB
ub 2)
Teleprot. Dist. SP on
off
on * LED BI BO 29 35 1 Yes
4036 >Dis.Tele. Unblocking: BLOCK
Channel 2 (>Dis.T.UB bl 2)
Teleprot. Dist. SP on
off
on * LED BI BO 29 36 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Inputs
Function Key
Relay
Chatter suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents