Operator control at the device
3.1 Setting the output voltage and response threshold value of the output current
Power supply system SITOP PSU8600
Manual, 09.2018, A5E36758446-5-76
83
Assigning the potentiometers to the outputs for the 6EP4436-8XB00-0DY0 expansion
module:
Voltage potentiometer for two outputs
Current potentiometer for two outputs
Setting the output voltage
● Using a screwdriver, at the voltage potentiometer, set the notch on the inner ring to the
required value.
A setting 15 V is shown in the following diagram.
Value range: 4 to 28 Volt.
Factory setting: 24 Volt.
Setting the response threshold value of the output current
● Using a screwdriver, at the current potentiometer, set the notch on the inner ring to the
required value.
A setting of 2 A is shown in the following diagram.
Value range at the basic units depending on the type: 2 to 20 A or 4 to 40 A.
Value range at the expansion module depending on the type: 0.5 up to 2.5 A, 0.5 up to 5 A
or 0.5 up to 10 A.
Factory setting: relevant maximum value.