Service Protocol
AG05
Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 38 of 64
Command
Length
Reply
Description
yy = 21: reserved
yy = 22: reserved
yy = 23: reserved
yy = 24: Current limiting [%]
Range 25 110 % of nominal torque
(see chapter 8: Parameter description Parameter no.
29)
yy = 25: Baud rate RS485
0 = 19200
1 = 57600
2 = 115200
(see chapter 8: Parameter description Parameter no.
33)
yy = 26: Bus Timeout
Range 0 - 20 x100 ms
(see chapter 8: Parameter description Parameter no.
35)
yy = 27: Inching 2 Offset
Range 10 100 % der of inching speed
(see chapter 8: Parameter description Parameter no.
30)
yy = 28: Key function enable
0 = all functions via key enabled
1 = all functions via key disabled
(see chapter 8: Parameter description Parameter no.
38)
yy = 29: Key enable time
Range 1 - 60 seconds
(see chapter 8: Parameter description Parameter no.
37)
yy = 30: Display orientation
0 = 0°
1 = rotated by 180°
(see chapter 8: Parameter description Parameter no.
45)
yy = 31: Display divisor
0 = 1
1 = 10
2 = 100
3 = 1000
(see chapter 8: Parameter description Parameter no.
43)