vi
Appendix B. Power Supply Adjustment and
Troubleshooting
Introduction.............................................................................................. B-1
In this Appendix....................................................................................... B-1
Adjusting the AC Power Supply Brownout Potentiometer.......................... B-2
Overview.................................................................................................. B-2
Using a Variac to Adjust the Brownout Potentiometer............................ B-2
Checking AC Power Supply Transformer / Bridge Rectifier....................... B-3
Checking DC Voltage at H1 and H2........................................................ B-3
Checking Connectors............................................................................... B-3
Replacing the Line Voltage Transformer and Bridge Rectifier ............... B-5
Checking EPS Transformer / Bridge Rectifier............................................. B-6
Introduction.............................................................................................. B-6
Checking DC Voltage from EPS Bridge Rectifer.................................... B-6
Checking Connectors............................................................................... B-7
Replacing the EPS Line Voltage Transformer and Bridge Rectifier ....... B-8
Appendix C. Diagnostic Utilities, Basic Service
Procedures, and Known Solutions
Introduction...............................................................................................C-1
In this Appendix........................................................................................C-1
N2 Comm Diagnostics..................................................................................C-2
Procedure ..................................................................................................C-2
IDNet Diagnostics.........................................................................................C-3
Procedure ..................................................................................................C-3
Duplicate Devices .....................................................................................C-3
Weak Answer Devices..............................................................................C-3
IDNet Earth Fault Search Diagnostics ..........................................................C-4
Procedure ..................................................................................................C-4
Network Diagnostics.....................................................................................C-5
Network Diagnostics.................................................................................C-5
Walk Test......................................................................................................C-6
Overview...................................................................................................C-6
Using Walk Test .......................................................................................C-6
Important Notes ........................................................................................C-6
TrueTest........................................................................................................C-7
Overview...................................................................................................C-7
Using TrueTest .........................................................................................C-8
Basic Service Procedures..............................................................................C-9
Restoring the 4010’s Default Programming..............................................C-9
Determining the BIN File Software Revision...........................................C-9
Disabling the Piezo on a Remote LCD Annunciator ................................C-9
Clearing an Event Overflow Trouble........................................................C-9
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Other manuals for Simplex 4010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4010 and is the answer not in the manual?

Simplex 4010 Specifications

General IconGeneral
DisplayLCD
Power Supply120/240 VAC, 50/60 Hz
ManufacturerSimplex
Model4010
Battery Backup24 VDC
NAC Outputs4
Max Detectors250
Max Modules250
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity RangeUp to 93% RH, non-condensing

Related product manuals