Simrad GC80/85 Compact MK2 Gyro Compass
988-12718-003 72
Main
category
Sub
category
Parameter/description
Default
value
Range
A-2
2.1.o Bearing offset A (°)
Offset value included in the “master bearing” and
used for correction of fixed error (°). If the Master
compass cannot be mounted parallel to the vessel’s
fore-after line, this parameter is used to compensate
for a small mounting error.
0.0 0.0 359.9
2.2.O Bearing offset B (°)
Value for general bearing error correction to enter to
Master compass bearing. It is used to correct the
bearing if the bearing for some reason deviates from
correct heading.
This value is cleared when it passes the zero-cross pin
or when power is switched OFF.
0.0 0.0 359.9
2.3.h Zero-cross bearing (°)
Absolute bearing set for MCU board when zero-cross
pin was passed during start-up sequence (last
azimuth operation) and normal running operation.
Zero-cross bearing can be set in this menu, but is
normally set up by measuring position (angle) of the
zero-cross pin in the Master compass by the test
mode A.
345.3 0.0 359.9
2.4.E Zero-cross error allowance (°)
Zero-cross alarm limit. The compass will generate a
zero cross alarm when the difference between the
zero-cross bearing and the relative bearing exceeds
this zero cross value.
This value should be set every time the zero-cross pin
is detected.
2.0 0.0 5.0
2.5.y Year
Used for setting current year.
- 2000 - 2099
2.6.N Month and Day
Used for setting current month and date.
- -
2.7.t Hour and Minute
Used for setting current hour and minute.
- -
2.8.d Total days of operation
This value should be reset after the installation is
completed.
- -

Table of Contents