Simrad GC80/GC85 Dual Gyro Compass
106 20221537 / D
SWITCH DEFAULT FUNCTION DESCRIPTION
SW2-1 OFF
SW2-2 OFF
No output
SW2-1 OFF
S2-1 OFF
SW2-2 ON
Output for old monitor
SW2-1 ON
SW2-2 OFF
Output for new monitor
SW2-1 ON
S2-2 OFF
Data output for record
SW2-2 ON
No output
S2-3 OFF Not used.
S2-4 OFF Pendulum ferry
OFF = Not connected/Buzzer stop enable
ON = Pendulum function in use/Buzzer
stop disable
SW2-5 OFF
SW2-6 OFF
= 1sec (1Hz)
SW2-5 OFF
S2-5 OFF
SW2-6 ON
= 100msec (10Hz)
SW2-5 ON
SW2-6 OFF
= 200msec (5Hz)
SW2-5 ON
S2-6 ON
Serial signal transmit
frequency IEC61162-1
ed.2
SW2-6 ON
= Invalid
S2-7 OFF Alarm mask setting
OFF = No alarm mask
ON = Control power abnormal
S2-8 OFF Not used.
S3-1 OFF Timer startup OFF = No, ON = Yes
S3-2 OFF
Talker ID of “ROT”
sentence
OFF = “HE”, ON = “TI”
SW3-3 OFF
SW3-4 OFF
Max 30.0 °/min.
SW3-3 OFF
S3-3 ON
SW3-4 ON
Max 300.0 °/min.
SW3-3 ON
SW3-4 OFF
Max 120.0 °/min.
SW3-3 ON
S3-4 OFF
Rate of turn scale
SW3-4 ON
Invalid
S3-5 OFF
Ban or permission of a
“ROT” sentence output
Valid at the time of external sensor
(standard) selection.
OFF = Disabled, ON = Enabled