DIP SWITCH SETTINGS
20221537 / D 105
11.4 SCC board 1 and 2
BT1
J10
J9
4
4
2
2
4
J8
3
1
3
3
1
J4
SW2
6
2
J7
2
2
J6
J5
SW1
ON
ON
ON
SW3
ON
SW4
5
1
1
1
8
1
1
1
8
1
8
6
U1
J3
U52
J1
21
J2
DIP switch settings on SCC boards
SWITCH DEFAULT FUNCTION DESCRIPTION
S1-1 - Control unit type OFF = Expanded, ON =Compact
S1-2 OFF Master compass type OFF = Standard, ON =High Speed
S1-3 ON Single or dual system OFF = Single, ON =Dual
S1-4
3
OFF
S1-4
4
ON
Dual gyro system
NOTE:
Different settings for SSC board 1 and
SSC board 2! Refer footnote below.
SW1-5 OFF
SW1-6 OFF
No external sensor
SW1-5 OFF
S1-5 OFF
SW1-6 ON
Magnetic system connected
(back-up)
SW1-5 ON
SW1-6 OFF
External sensor connected
SW1-5 ON
S1-6 OFF
External sensor
connection
SW1-6 ON
External system connected
(back-up)
S1-7 OFF Serial signal format OFF = IEC61162-2 (NMEA0183, ref. page 4),
ON = Tokimec
S1-8 OFF Alarm output setup OFF = All alarms,
ON = Only power failures
3
SSC board 1 (for Gyro 1): OFF
4
SSC board 2 (for Gyro 2): ON

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing

Related product manuals