  • E
    Emily MillerAug 19, 2025
    How to fix Simrad Marine Equipment MX610/MX612 unit that fails to turn ON?
    • G
      grichardsAug 19, 2025
      To address a unit that fails to turn ON, ensure the power cable is properly connected to the back of the MX610/MX612 and that the 12-24 VDC power is active. Note that the unit typically requires about 30 seconds to reboot after power is reconnected. Also, inspect the power cable's in-line fuse (or circuit-breaker) and replace it if it's blown. Using a voltmeter, confirm that the 12-24 VDC supply is present on the power cable connector pins. If the issue persists, consider replacing the MX610/MX612 unit.
  • M
    marissa18Aug 22, 2025
    What to do if Simrad Marine Equipment AIS targets are not detected?
    • A
      Aaron SmithAug 22, 2025
      If AIS targets are not being detected, first verify that an AIS transponder is connected to the N2K bus and that the AIS transponder is turned on. Inspect the VHF antenna, coaxial cable, and connectors for any signs of damage. If the problem continues, consider replacing the AIS transponder.
  • D
    Donna LyonsAug 26, 2025
    Why is True Heading not displayed on my Simrad Marine Equipment?
    • K
      Kristen BatesAug 26, 2025
      If true heading is not displayed on your Simrad Marine Equipment, verify that the data source selected under the MENU/Data sources/ Compass is either the HS70/HS80/MX575C or Gyro. Perform an auto-select procedure or manually select the correct GPS compass unit. If the problem persists, replace the GPS compass antenna unit.
  • J
    Jennifer GibsonAug 28, 2025
    How to troubleshoot a CAN bus failure on Simrad Marine Equipment?
    • K
      Kathy PerryAug 28, 2025
      If you are experiencing a CAN bus failure with your Simrad Marine Equipment, check the following: 1. Ensure that the backbone terminations are correct. 2. Inspect the cables and connectors for any defects. 3. Replace the N2K power supply or the MX61xJB junction box unit.
  • L
    Lauren BoydAug 30, 2025
    How to brighten a dim display on Simrad Marine Equipment?
    • J
      Jason AguirreAug 30, 2025
      If the display on your Simrad Marine Equipment is dim, try pressing the power button momentarily to increase the backlight brightness.
  • J
    Jon PearsonSep 1, 2025
    What does a red flashing power button and black display mean on Simrad Marine Equipment?
    • C
      Chris MatthewsSep 1, 2025
      If the power button on your Simrad Marine Equipment is flashing red and the display is black, it indicates that the local supply voltage is either missing or below 5 V. Check the local power supply, connections, and fuses. To resolve this, press and hold the power button for 5-6 seconds to completely turn off the unit, then repower it by pressing the power key again.
  • M
    Michele GloverSep 3, 2025
    What causes low CAN bus voltage on Simrad Marine Equipment?
    • L
      Leonard RomeroSep 4, 2025
      If you are experiencing low CAN bus voltage with your Simrad Marine Equipment, check the cable length, bus load, and bus supply feeding point. If possible, check if the fault disappears by disconnecting some units.
  • H
    Henry DavisSep 5, 2025
    How to fix Simrad GN70 Marine Equipment when unit fails to turn ON?
    • C
      Carlos TorresSep 5, 2025
      If the Simrad Marine Equipment unit fails to turn on, ensure the power cable is securely plugged into the back of the unit and that the 12-24 VDC power supply is switched on. Note that the unit typically requires about 30 seconds to reboot after power is reconnected. Also, inspect the power cable's in-line fuse (or circuit-breaker) and replace it if it's blown. Use a voltmeter to confirm that the 12-24 VDC supply is present on the power cable connector pins. If the problem continues, consider replacing the unit.
  • J
    Joshua RobinsonSep 8, 2025
    What to do if AIS targets are not detected on Simrad GN70 Marine Equipment?
    • S
      Sherri WoodSep 8, 2025
      If AIS targets are not being detected by your Simrad Marine Equipment, first verify that an AIS transponder is connected to the N2K bus and that the AIS transponder is turned on. Inspect the VHF antenna, coaxial cable, and connectors for any signs of damage. If the problem persists, the AIS transponder may need to be replaced.
  • E
    Elaine MitchellSep 10, 2025
    What does red flashing power button mean on Simrad GN70?
    • E
      ellisandresSep 10, 2025
      If you observe a red flashing power button and a black display on your Simrad Marine Equipment, it indicates that the local supply voltage is either missing or below 5 V. Check the local power supply, connections, and fuses. To completely turn off the unit, press and hold the power button for 5-6 seconds, then repower it by pressing the power key again.

Simrad GN70 Specifications

General IconGeneral
Display TypeTFT LCD
Display Resolution800 x 480 pixels
GPSYes
ChartplotterYes
SonarNo
Waterproof RatingIPX7
AISYes
Operating Voltage12/24 V DC
CompassYes
Power Supply12/24 V DC
Operating Temperature-15°C to +55°C
NetworkingNMEA 2000
Display Size7 inches
GPS ReceiverHigh-sensitivity
Storage Temperature-20°C to +70°C

Related product manuals