92 |
Specications | GN70/MX610/MX612 Operator and Installation Manual
GN70/MX61x Connector Pinouts
2 31
1 Power
2 N2K bus
3 Ethernet
Power
Cable connector (female - front view)
Layout Pin Wire color Function
4
1 8
3
2
1
1 Black Battery (-)
2 Blue Alarm/Active
3 Yellow External command
4 Red Battery (+), 12 - 24 V DC
Power cable
2 m (6.5 ft)
CAN/NMEA 2000/SimNet
Micro-C cable connector (female - front view)
Layout Pin Wire Color Function
1
1 8
4
3
2
1
2
3
4
5
1 (Bare) Shield
2 Red NET S (+12 V)
3 Black NET C (-)
4 White NET H
5 Blue NET L
Ethernet
¼ Note: Both straight and crossed Ethernet cables may be used for software upload!