MK6 related settings in the VarpPCI.ini file
For compatibility with older versions, the name of ini file is VarpPCI.ini
[General]
DataSource=mk6
[LAN]
MK6IPAddress=192.168.5.100
MK6CommandPort=5062
VideoInPort=5060
IP address and command port in this ini file must correspond to the settings in the MK 6.0
Radar Interface box configuration file (see "Configuration page" on page 17 of the MK 6.0 Radar
Interface box WEB interface). VideoInPort is not configured in the MK 6.0 Radar Interface box.
This configuration is sent to the MK 6.0 Radar Interface box as a part of a data request.
VarpPCI sends the requests to the MK 6.0 Radar Interface box periodically. The MK 6.0 Radar
Interface box has the timeout parameter. If the message sending delay exceeds the timeout
value, the MK 6.0 Radar Interface box stops sending the video signal.