INTEGRATION WITH SKF @PTITUDE OBSERVER
Enlight Collect IMx-1 System View
SKF Enlight Collect IMx-1 System
User Manual
Revision F
Connection:
• Connected
• Closed
Firmware Version: The version of firmware, installed in the gateway.
Sensors: The number of sensors linked to the gateway.
IP Address: The IP address that is used by the gateway.
2.3.2 Sensors
Similarly, for sensors the following properties are shown in the sensor table:
Name: Name given to the sensor.
Hardware ID: The unique identifier for the sensor, if the sensor is commissioned and
has successfully connected via the gateway to @ptitude Observer, it will show a
MAC address in this field.
Location: For a measurement sensor, Leaf or Mesh, the hierarchical location where
that sensor and measurement points have been created. For a relay node, this field
contains the descriptive location information entered by the user,
Figure 25.
Self diagnostics status: Displays the latest reported self-diagnostic status or in
case of multiple errors the item considered most critical. The status field will initially
be empty until the actual sensor status has been received.
• "Ok" or an error of any of the following types. Values in brackets are decimal
values corresponding to the bit set in the mesh network information log, Self-
Diagnostic entry, when the error is true:
o Battery level low (1)
o External Flash memory failure (16)
o Configuration CRC failure (64)
o Firmware update error (128)
o (Watchdog reset (256) – only available in the log file)
o Network instability (512)
Self-diagnostic errors may also raise a system or critical system alarm in @ptitude
Observer. Note that the network instability error can have significant ramifications for
sensor battery life and urgent action should be taken, refer to
IMx-1 sensor
troubleshooting
.
Double clicking a sensor entry or selecting it and then choosing Edit, will launch the
sensor properties dialog where extended status information can be viewed on the
second tab, named Status.