4. Technical data
4.1 Technical connection data
Table 8
Technical connection data
Designation
Value
<Content>
Reservoir capacity
2, 3 and 6 liters
Reservoir material
MKU, MKL
Plastic or metal
MKF
Plastic
Weight empty
Unit with 2-liter plastic reservoir
3.4 kg
Unit with 3-liter plastic reservoir
4.2 kg
Unit with 3-liter metal reservoir
5 kg
Unit with 6-liter plastic reservoir
5.6 kg
Delivery rate
1)
MKU, MKL
0.1; 0.2; 0.5 l/min
MKF
0,1; 0,2 l/min
Max. operating pressure
30 bar
Pressure limiting valve
30 bar
Pressure-relief valve
Included
Operating temperature
+10 to 40 °C
Protection class according to DIN EN 60529 (VDE 0470-1)
IP 54
Pumped media
MKU, MKL
Mineral oil and synthetic oil
Operating viscosity
20–1500 mm 2 /s
MKF
Fluid grease of NLGI grade 000 or 00, compatible with plastics,
NBR elastomers, copper and copper alloys
AC motor
Rated frequency
50 Hz
60 Hz
Rated voltage
115/230 V
115/230 V
Rated current
1,06/0,53 A
1,36/0,68 A
Rated capacity
60 W
75 W
Rated speed
2600/3050 rpm
Operating mode according to DIN EN 60034-1 (VDE 0530-1)
2)
S3, 20 % (1.25 to 25 min)
With integrated thermostat
Recommended fuse for line protection according to
DIN EN 60898
B 6A
DC motor
Rated voltage
24 V DC
Rated current
1.6 A
Starting current
4 A
Rated capacity
39 W
Rated speed
1650 1/min
Operating mode according to DIN EN 60034-1
(VDE 0530)
2)
S3, 20 % (1.25 to 25 min)
Integrated device protection for motor, cartridge fuse-link
(5×20
mm)
according to DIN EN 60127-2 (VDE 0820-2) standard sheet 3
T2 A
4)
Recommended fuse for line protection according to
DIN EN 60898
B 6A or C 4A