EasyManua.ls Logo

Skyjack SJ61T - 4.1-4 Engine Will Not Crank from Base; 4.1-5 Engine Will Not Crank from Platform

Skyjack SJ61T
232 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Telescopic Boom Series
Models SJ61T & SJ66T
194312
December 2007 Page 113
Section 4 - Troubleshooting Information Service and Maintenance
4.1-3 No Power to Base
1. Open or defective base key switch S2.
- Select base position on key switch. Check continuity through base key switch. Replace if
defective.
2. Loose or broken wire #12 from base key switch S2 to Ignition/E-pump switch S5.
- Check continuity. Replace if defective.
3. Loose or broken wire #12 from base key switch S2 to base connector plug A pin #5.
- Check continuity. Replace if defective.
4. Loose or broken wire #12 in boom cable A or its connectors.
- Check for continuity between pins #5 on cable A. Check for loose or corroded connections on
cable connectors. Replace if wire is defective.
5. Loose or broken wire #12 from plug A pin #5 to emergency stop switch S4 in platform control console.
- Check continuity. Replace if defective.
6. Open or defective emergency stop switch S4.
- Check switch is in on position. Check continuity through switch. Replace if defective.
7. Loose or broken wire #10 from emergency stop switch S4 to plug A pin #4.
- Check continuity. Replace if defective.
8. Loose or broken wire #10 in boom cable A or its connectors.
- Check for continuity between pins #4 on cable A. Check for loose or corroded connections on
cable connectors. Replace if wire is defective.
9. Loose or broken wire #10 from plug A pin #4 to base terminal block.
- Check continuity. Replace if defective.
10. Open or defective diode D10.
- Check diode. Replace if defective.
11. Loose or broken wire #10 from base terminal block to Ignition/E-pump (enable) switch S5.
- Check continuity. Replace if defective.
12. Open or defective Ignition/E-pump (enable) switch S5.
- Check switch. Replace if defective
4.1-4 Engine Will Not Crank from Base
1. Loose or broken wire #57A from base start switch S5 to relay 57ACR (Deutz D2011 and GM 3.0l engines).
- Check continuity. Replace if defective.
2. Defective base start switch S5.
- Check start switch. Replace if defective.
4.1-5 Engine Will Not Crank from Platform
NOTE
Engine will not crank from platform with footswitch depressed.
1. Loose or broken wire #4 from emergency stop switch S4 to start switch S6.
- Check continuity. Replace if defective.
2. Defective start switch S6.
- Check continuity through switch. Replace if defective.
3. Loose or broken wire #57 from start switch S6 to relay 08CR.
- Check continuity. Replace if defective.
4. Defective relay 08CR.
- Check continuity through contacts of relay. Replace if defective.
5. Loose or broken wire #57A from relay 08CR to plug B pin #14.
- Check continuity. Replace if defective.

Table of Contents