EasyManuals Logo

Skyjack SJ61T Service Manual

Skyjack SJ61T
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
Telescopic Boom Series
Models SJ61T & SJ66T
194312
December 2007 Page 131
Section 4 - Troubleshooting Information Service and Maintenance
4.1-37 No Platform Rotate or Jib Function from Platform Control Console
1. Loose or broken wire #08 from platform terminal block to rotate switch S20 and jib switch S21.
- Check continuity. Replace if defective.
2. No output on pin #21 of the valve driver to wire #42.
- Check pin #20 for minimum 3.5 volts. If no voltage present with foot on footswitch check section
5 for OCM pin voltage reference.
3. Loose or broken wire #42 from valve driver pin #21 to plug B pin #24 in platform control console.
- Check continuity. Replace if defective.
4. Loose or broken wire #42 in boom cable B or its connectors.
- Check for continuity between pins #24 on cable B. Check for loose or corroded connections
on cable connectors. Replace if wire is defective.
5. Loose or broken wire #42 from base connector plug B pin #24 to base key switch S2.
- Check continuity. Replace if defective.
6. Loose or broken wire #42 from base key switch S2 to turret harness plug pin #16.
- Check continuity. Replace if defective.
7. Loose or broken wire #42 from turret harness plug pin #16 to proportional ow enable valve 2H-42.
- Check continuity. Replace if defective.
8. Loose or broken wire #02 from turret harness plug to proportional ow enable valve 2H-42.
- Check continuity. Replace if defective.
9. Defective proportional ow enable valve 2H-42.
- Check continuity and resistance through coil. Replace if defective.
4.1-38 No Platform Rotate Left from Platform Control Console
1. Defective platform rotate switch S20.
- Check continuity through switch while activating rotate left function between wires #08 and #36.
2. Loose or broken wire #36 from platform rotate switch S20 to platform terminal block.
- Check continuity. Replace if defective.
3. Loose or broken jumper wire #36 on platform terminal block.
- Check continuity. Replace if defective.
4. Open or defective diode D36 in platform terminal block.
- Check diode. Replace if defective.
5. Loose or broken wire #36A from platform terminal block to valve driver pin #17.
- Check continuity. Replace if defective.
6. Loose or broken wire #36 or #02 from platform terminal block to rotate left valve 4H-36.
- Check continuity. Replace if defective.
7. Defective rotate left valve coil 4H-36.
- Check continuity and resistance through coil. Replace if defective.
4.1-39 No Platform Rotate Right from Platform Control Console
1. Defective platform rotate switch S20.
- Check continuity through switch while activating rotate right function between wires #08 and
#37.
2. Loose or broken wire #37 from platform rotate switch S20 to platform terminal block.
- Check continuity. Replace if defective.
3. Loose or broken jumper wire #37 on platform terminal block.
- Check continuity. Replace if defective.
4. Open or defective diode D37 in platform terminal block.
- Check diode. Replace if defective.
5. Loose or broken wire #36A from platform terminal block to valve driver pin #17.
- Check continuity. Replace if defective.
6. Loose or broken wire #37 or #02 from platform terminal block to rotate right valve 4H-37.
- Check continuity. Replace if defective.
7. Defective rotate right Valve coil 4H-37.
- Check continuity and resistance through coil. Replace if defective.

Table of Contents

Other manuals for Skyjack SJ61T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ61T and is the answer not in the manual?

Skyjack SJ61T Specifications

General IconGeneral
BrandSkyjack
ModelSJ61T
CategoryLifting Systems
LanguageEnglish

Related product manuals