December 2007 Page 151
Section 5 - Procedures Service and Maintenance
General
The following information is provided to assist you in the use and application of servicing and maintenance procedures
contained in this chapter.
Safety and Workmanship
Your safety, and that of others, is the rst consideration when engaging in the maintenance of equipment. Always
be conscious of weight. Never attempt to move heavy parts without the aid of a mechanical device. Do not allow
heavy objects to rest in an unstable position. When raising a portion of the equipment, ensure that adequate support
is provided.
Platform
5.1-1 Human Machine Interface (HMI)
Maintaining proper calibration is essential for good performance of the aerial platform.
1. Ensure aerial platform is on a rm level surface, and is in stowed position and engine is off.
2. On base control, turn base/off/platform key switch to “ " platform position.
3. Pull out " " emergency stop button.
WARNING
Ensure that you maintain three points of contact to mount/dismount platform.
3. Enter platform and close gate.
WARNING
DO NOT operate any control on platform control console without proper fall protection secured to
designated location in platform. Failure to avoid this hazard could result in death or serious injury!
WARNING
Ensure that there are no personnel or obstructions in test area and that there is sufcient room
for boom to swing.
4. At platform control, open the cover of the console to access the OCI-1 console.
The OCI-1 has an integrated multi segment, two line display with membrane keys that allow it to be used as the
main interface to system controls and adjustments. the Human Machine Interface (referred to as the HMI) will serve
as your window into the application software to allow the operator to monitor/adjust the following information;
- Active Function Being Used
- Part Number and Serial Number
- Restore the Factory Default Settings
- Output Calibrations (Tresh, Max, Ramp.etc)
- I-O Status
- CANBus Status

Table of Contents

Other manuals for Skyjack SJ61T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ61T and is the answer not in the manual?

Skyjack SJ61T Specifications

General IconGeneral
BrandSkyjack
ModelSJ61T
CategoryLifting Systems
LanguageEnglish

Related product manuals