Telescopic Boom Series
Models SJ61T & SJ66T
194312
December 2007 Page 17
Section 1 - Scheduled Maintenance Scheduled Maintenance Inspections
• Fuel Tank (B,C)
IMPORTANT
Before using your aerial platform en-
sure there is enough fuel for expected
use.
- Ensure fuel ller cap is secure.
- Ensure tank shows no visible damage
and no evidence of fuel leakage.
• Fuel Tank Leaks (B)
- Ensure that there no fuel leaks at tank.
DANGER
Engine fuels are combustible. Inspect
the aerial platform in an open, well-
ventilated area away from heaters,
sparks and ames. Always have an
approved re extinguisher within easy
reach.
- Ensure fuel tank, shutoff valve, hoses and
ttings show no visible damage and no
evidence of fuel leakage.
Hydraulic Tank
Base Control
Console
Fuel Tank
Emergency Power
Unit
Brake Manifold
Hydraulic Return
Main Manifold
High Pressure Filter