Telescopic Boom Series
Models SJ61T & SJ66T
194312
December 2007 Page 203
Section 5 - Procedures Service and Maintenance
5.6-2 Diagnostic Trouble Codes (continued)
DTC
(J1939)
SPN
(J1939)
FMI
DetectedItem/Hardware
341 723 2
‐Cam+orCam‐circuitsinwrongconnectorterminalslot
‐LossoffeedvoltagetoCamsensor
‐Lossofsensorfeed
‐Opensensorground
‐Openorshortedtogroundsignalwire
‐Sensormalfunctioning
342 723 4
‐LossoffeedvoltagetoCamsensor
‐Lossofsignalorgroundcircuits
‐Faultysensor
359 n/a n/a n/a
420 3050 n/a n/a
524 100 1 ‐LowOilPressure
562 168 17
‐Wiringharnessopen/short/damage
‐Batteryabnormality
563 168 15 ‐Systemvoltageabnormality(HighSide)
601 628 13
‐FaultyECU
‐ROMMalfunction
604 630 12 ‐FaultyECU
606 629 31 ‐FaultyECU
627 1348 5
‐Opencoilinrelay
‐Openinrelaydrivercircuitinengineharness
628 1347 5
‐Relaypullincoilshortedinternally
‐Relaydrivercircuitshortedtogroundinwireharness
629 1347 6
‐Shortedrelaypullincoil
‐Relaydrivercircuitshortedtovoltageinwireharness
642 1079 4
‐Wiringharnessshorttoground
‐ECMmalfunction
643 1079 3
‐Wiringharnessshortto12.0Vpower
‐ECMmalfunction
652 1080 4
‐Wiringharnessshorttoground
‐ECMmalfunction
653 1080 3
‐Wiringharnessshortto10.0Vpower
‐ECMmalfunction
686 1485 4
‐Shorttogroundinrelaypullincoil
‐Shorttogroundinrelaydrivercircuitinwireharness
687 1485 3
‐Shortedrelaypullincoil
‐Relaydrivercircuitshortedtovoltageinwireharness
‐PowerRelayError
1111 515 16 ‐Engineoverspeedcondition, faulty Cranksensororinput
1112 515 0 ‐Engineoverspeedcondition,faultyCrank
sensororinput
1151
4236 0
•exhaustleaksupstreamorneartheHEGOsensor
•reducedfuelsupplypressuretothegaseousfuelcontrolsystem
•afuelsupplyormanifoldleak
•anon‐responsiveHEGOsensor