67
Use and maintenance manual S440-S560-S560N-S560NA-S870
Check the correct operation of the board cooling fan.
Check the correct operation of the cooling fan of the boards zone, in the machines that are
equipped with this fan.
If the problem persists, stop the sealing and heat-shrinking operations, switch the machine off
and call the servicing centre.
ERROR 6: NTC cooling wing temperature too high
Solution:
Switch the power off and check that the air intakes are not blocked.
Check the correct operation of the board cooling fan.
Check the correct operation of the cooling fan of the boards zone, in the machines that are
equipped with this fan..
If the problem persists, stop the sealing and heat-shrinking operations, switch the machine off
and call the servicing centre.
ERROR 7: NTC temperature exceeding the valid limits
Solution:
Make sure that the cooling fan is operating correctly
Make sure that the ambient temperature is < 40° C
If the problem persists, switch the machine off and call the servicing centre.
ERROR 8: Calibrating parameters error
The memory data are corrupted.
Solution
Switch the machine off and then on again
If the problem persists, switch the machine off and call the servicing centre.
ERROR 9: EEPROM error
An anomaly has occurred during data storage.
Solution:
Press the key + and then reset the correct machine model
If the problem persists, switch the machine off and call the servicing centre.
ERROR 10: 24V outputs over-current error
Solution:
Switch the power off and check the integrity of the electromagnet connection cables.
If the problem persists, stop the sealing and heat-shrinking operations, switch the machine off
and call the servicing centre.
ERROR 13: Closed bell micro error
At the START, if the bell does not descend, an error is signalled
Solution:
Check the correct connection of the bell automatism motor and the motor electrical
operation.
Check the mechanical operation of the bell descent.
Check the correct operation of the closed bell micro (EF010050).
Check the fuses F2 and F3 situated on the module FLEXTRON-PWR OUT. (=FLEXTRON
BELL)
If at the START the bell comes down but an error is indicated:
Check the correct operation of the closed bell micro (EF010050).
Check the mechanics of the machine: the increase in frictions, in the bell lowering motion,
can cause a slow down such to indicate error.
If the problem persists, switch the machine off and call the servicing centre.