68
ERROR 14: Open bell micro error
Solution:
Check the operation of the open bell micro (EF010049).
Check the correct connection of the bell automatism motor.
Check the fuses F2 and F3 situated on the bell inversion module.
If the problem persists, switch the machine off and call the servicing centre.
ERROR 15: Bell opening time error
Solution:
Check the operation of the open bell micro (EF010049)
Check the correct connection of the bell automatism motor.
Check the fuses F2 and F3 situated on the bell inversion module.
Make sure that the bell descent is not hindered by any obstacles or frictions
If the problem persists, switch the machine off and call the servicing centre.
ERROR 16: Relay switch error
Solution:
Check the correct connection of the emergency button and the relay switch correct
operation.
If the problem persists, switch the machine off and call the servicing centre.
ERROR 18: Bell closing and opening micro simultaneously pressed
Solution:
Make sure that the bell opening micro is operating correctly.
Make sure that the bell closing micro is operating correctly.
If the problem persists, switch the machine off and call the servicing centre.
ERROR 100 - ERROR 101 - ERROR 110 - ERROR 111
Error caused by the FLEXTRON POWER BASE
Solution:
check the correct operation of the FLEXTRON POWER BASE.
check the connection cable, especially the connectors.
replace the board FLEXTRON POWER BASE.
If the error persists after replacing the FLEXTRON POWER BASE, it might be caused by the
CPU board transmitter.
ERROR 200 - ERROR 201 - ERROR 210 - ERROR 211
Error caused by the connection between the FLEXTRON POWER BASE and the FLEXTRON-
PWR OUT. (=FLEXTRON BELL)
Solution:
check the connection cable, especially the connectors.