EN
ATySpM - 542935E - SOCOMEC
STEP 5
Programming
Check
STEP 4
Whilst in manual mode, check the wiring and if ok power
up the product.
Product programming
Programming access is possible in Automatic mode, when the product is in position I with source 1
available, and in Manual mode in any position and with at least one available source.
Note: For complete programming details: download theinstruction manual from the Socomec website.
STEP 6A
Automatic
operation
Close the front cover as
shown to put the product
into automatic mode.
STEP 6B
Manual operation
Open the front cover as
shown to put into manual
mode.
Use the handle situated in
the front panel under the cover to operate the
transfer switch.
Check the changeover switch position on the
indicator before operating.
To simplify operation
use the handle with the
extension provided.
(Max 8 Nm)
II
I
o
0,5 to 2,5 mm
2
#28 to #14 AWG
0,5 to 2,5 mm
2
#28 to #14 AWG
6 mm / 0,236"
Slotted head 2,5 mm
90º 90º
Extension
STEP 6C
Padlocking mode
In order to padlock put the
product in manual mode.
Pull the locking mecha-
nism and insert a padlock
as shown.
As standard padlocking in the 0 position.
Configurable to I-0-II (see step 1).
1x 4-8 mm
To access programming
Default code: 1000
Browsing
1 2
1 2
Press for 3 s
1 2
21
To modify the
value ofthis
digit
1 2
1 2
1 2
To access the
other digits
1 2
1 2
Validate entry
Exit programming
1 2
Press the validate
button for
3seconds.
TIMERS Setting range Defaut Value
1FT Loss of source 1 Validation timer. 0 to 60 sec
(1)
3 sec
1RT Source 1 return validation timer. 0 to 3600 sec 180 sec
2FT Loss of source 2 Validation timer. 0 to 60 sec 3 sec
2RT Source 2 return validation timer. 0 to 3600 sec 5 sec
2AT Standby network stability validation before transfer 0 to 3600 sec 5 sec
2CT Run on timer. 0 to 600 sec 180 sec
ODT Dead band timer. 0 to 20 sec 3 sec
Parameters Setting range Default value
NEUTRAL Neutral position on the switch
AUTO: neutral position is automaticaly detected when the product is supplied
the first time.
LEFT: neutral must be connected to the left that means on the terminal 1 from
each switch.
RIGHT: neutral must be connected to the right that means on the terminal 7 from
each switch.
AUTO
LEFT
RIGHT
AUTO
NOM. VOLT. Nominal voltage
Phase/phase or phase/neutral in 1BL and 41NBL
From 180 to 480 Vac 400Vac (230/400V version)
230Vac (127/230V version)
NOM. FREQ. Nominal Frequency 50 or 60Hz 50Hz
APP Type of application
M-G: network - Genset
M-M: network - network
M-G
M-M
M-G
RETRANS Retransfer inhibit feature, press on Validation button required to allow retransfer
form Gen to Main
YES or NO NO
NETWORK Network configuration* 3NBL / 4NBL / 41NBL / 1BL
(230/400V version)
4NBL / 3NBL / 2NBL / 42NBL
(127/230V version)
4NBL
(1) O to 3600 secs in M-M network
* The wiring must be adapted to the network configuration. Below, the main configuration types.
3 phase / 4 wire 3 phase / 3 wire 2 phase / 3 wire 2 phase / 2 wire 1 phase / 2 wire
4NBL
4BL
1
32
N
3NBL
3BL
L1
L3 L2
NM
2NBL
1
2
3
2BL
1
3
1BL
1
N
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
(9)
(9)
(9)
1 2 1 2
1 21 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
21
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
(1)
(7)
(1)
(1)
(3)
(3)
(3)
(4)
(4)
1 2
(4)
(6)
1 2
(1)
(3)
(2)
(2)
(8)
(1)
(1)
(8)
(1)
(5)
(5)
(5)
(5)
(5)
1 2
Configure
parameters
Configure voltage
thresholds and
hysteresis
Frequency thresholds
and hysteresis
configuration
Timer configuration
Input - output
configuration
Communication
configuration
(1) Only accessible if the Setup menu variable “APP” is at “M-G”,
see Setup Menu
(2) Only accessible if the Setup menu variable “APP” is at “M-M”,
see Setup Menu
(3) Only accessible if one of the inputs is EON, see I/O Menu
(4) Only accessible if one of the inputs is EOF, see I/O Menu
(5) Only on the COMM version, see description in the option section
(6) Only accessible if one of the outputs is LSC, see I/O Menu
(7) Default values: 230V for version 127/230 400V for version
230/400
(8) only accessible when the “RETURN O” variable in the Setup menu
is set to “YES”, see SETUP menu.
(9) Only accessible if the associated input is configured.
* UNL = Unlimited
The entry point for programming mode is the SETUP menu.
1 2
Parameters must always be adjusted and verified for
compliance with the application.
The default values are loaded as standard.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the socomec ATyS p M and is the answer not in the manual?

socomec ATyS p M Specifications

General IconGeneral
Brandsocomec
ModelATyS p M
CategorySwitch
LanguageEnglish

Related product manuals