34
7
Print format
Query
Printout (OK)
Select
on or off
When on, a query asks after each print whether the printout was OK.
If not, the print is repeated until confirmed as OK.
Factory default: off
Printout on
G + T = 0
Select on or off
Off: No printout when scale is empty
Factory setting: on
Decimal delimiter
Select
Comma, period, or none
Factory default: comma
Thousand delimiter
Select
Comma, period, or none
Factory default: none
Suppress unit of measure
Select on or off
Off: Unit of measure is not suppressed
Factory default: off
Seq. number
Print key
Enter
The number for the first print format can be entered here. The function is
disabled if the value zero is entered. Starting with number 1, the value is
incremented by one after each output with the Print key.
Delete value after printout
Enter
Operated as per interface description 470.508.090
Factory default
Select
Do not execute: Customized settings in print format setting remain intact
Execute: Resets print format setting to factory defaults.
8
IT settings
(see interface description 470.508.090 for more details)
IT mode
Select
for IT mode (terminal automatically triggers the selected data record)
no sending of data record
A: send data record 1 x immediately
B: send data record 1 x weight change/settle
C: send data record change/settle
D: send data record change/settle/>empty
E: send data record change/settle/<empty/>empty
F: send data record continuously
G: send data record 3005 continuously
H: send data record 1 x on settle
Factory default: none