EasyManua.ls Logo

Solar-Log 300 - Performance Monitoring Notification

Solar-Log 300
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
Notifications
The output measured from the inverters is contrasted with the generator capacity that is listed in the sys-
tem.
A notification is sent (by email) when the deviation exceeds the amount configured (for example 10%) over
a set time period (for example 30 minutes).
Note!
For performance monitoring configurations, see the chapter "Configuring Notifi-
cations
" in the Installation Manual.
3.2.1 Performance Monitoring Notification
Example Notification:
Module Field 1 - Inverter 1 'Inverter 1 House'
IRV = 4916W ( Inverter 2, Inverter 2 House' ), IAV = 3950W, deviation = 19.65 %
The notification contains the following information:
Module field:
The module field which was affected or at least the module field in which a deviation was detected.
Deviating inverter:
Inverter 1
IRV:
The reference value that is used to contrast inverters. It comes from the most effective operating inverter,
the value is in W.
IAV:
The amount of output from inverter with a deviation.
Dev:
The amount of deviation as a percentage of the reference value.

Table of Contents

Other manuals for Solar-Log 300

Related product manuals