95
Operation on LCD
==Peak shaving mode==
>ChargeFromGrid
Reserved_SOC
===ChargeFromGrid===
ChargeFromGrid
> Enable <
===ChargeFromGrid===
ChargePowerLimits
1000W
===ChargeFromGrid===
>MAX_SOC
50%
• Reserved_SOC: Default: 50%; range: 10%-100%
»
It can be used in specific time period. In this period, inverter does not allow
taking grid energy to charge battery. PV is the only way to charge battery and
PV will charge the battery first. Inverter will not supply power to loads until
battery SOC higher than this value in order to save enough energy for later
shaving period.
==Peak shaving mode==
>Reserved_SOC
===ReservedSOC===
Reserved SOC
> 50% <
Setting Load Management
To use the heat pump function, you need to set the relevant parameters on LCD screen.
This is function is applicable for the first generation of SolaX Adapter Box.
a. Enter the Load Management interface through the path: Menu>Setting>User
Setting>Load Management
b. Set the Load Management mode. Overall three heat pump operation modes are
available for you to choose:
=====User Setting=====
Peak shaving mode
>Load Management
User PassWord
===Load Management===
>Mode Select
Disable
===Load Management===
>Mode Select
Manual
===Load Management===
>Mode Select
SmartSave
»
Mode 1 Disable: The Adapter Box function is disabled under this operation
mode.
»
Mode 2 Manual: In this operating mode, you can change the Adapter Box
from on to off, or from off to on through settings on the inverter or through
SolaX App.
»
Mode 3 SmartSave: In this operating mode, users can set a series of
parameters on the SolaX inverter to intelligently control how and when the