231Overview
Chapter 6 DME Wipes
Relation to processed keys
When using the DME for a processed key, if you select a DME wipe, an
available DME is automatically allocated to the DME wipe. If all of the DME
channels are in use, then it is not possible to select a DME wipe.
If in a Setup menu a setting has been made for DME allocation, that Setup
menu setting takes precedence (see “Setting the assignments of DME channels
to use on the individual M/E banks” in Chapter 20 (Volume 3).
Relation to resizer
It is not possible to select a DME wipe for a key having the resizer enabled.
Number of DME wipes that can be used simultaneously on a
single M/E bank
DME wipes can be used in five places, including the four independent key
transitions.
It is not possible to use two or more of these places simultaneously.