360
Simple P/P Software
Chapter 10 Special Functions
The status area shows the output ports and assigned primary inputs on the
left, and a list of primary inputs that can be assigned on the right.
2
Using any of the following methods, select the output port number and
signal to be assigned.
Press directly on the list in the status area to make the selection.
Press the arrow keys to scroll the reverse video cursor.
Turn the knobs.
3
Press [Set].
This assigns the primary input to the selected output port.
To clear a primary input assignment
Press [Inhibit].
This clears the assignment and “No Assign” is displayed in the Re-Entry
column.
Simple P/P Output Signal Selection on an M/E
You can select a simple P/P output on an M/E.
Preparations
Interface connection
Connect the simple P/P output signal to return to a primary input via a BNC
cable.
System setup
In the Engineering Setup >Switcher >Output >Simple P/P R-Entry Assign
menu, specifies the primary input to which the simple P/P output signal returns.
Selecting the input on an M/E bank
Select a primary input on the cross-point control block of an M/E bank. You
can select a simple P/P output signal with the same phase as that of the other
input signals.
Knob Parameter Adjustment Setting values
V1 Output No. Output port number 1 to 23
V2 Source No. Primary input number 0 to 49