Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-150-
flux-weakening running state. The flux-weakening
control coefficient can change the flux-weakening
curvature, the larger the coefficient, the steeper the
curve, the smaller the coefficient, the smoother the
curve.
Setting range of P03.22: 0.1–2.0
Setting range of P03.23: 10%–100%
P03.24 sets the max. output voltage of the VFD, which
is the percentage of rated motor voltage. This value
should be set according to field conditions.
Setting range:0.0–120.0%
Carry out motor pre-exciting during starting to build a
magnetic field inside the motor to improve the torque
characteristics of motor during starting.
Setting range: 0.000–10.000s
Flux-weakening
proportional gain
Vector control
speed display
0: Display as per actual value
1: Display as per the set value
Static friction
compensation
coefficient
Corresponding
frequency point of
static friction
High speed friction
compensation
coefficient
Corresponding
frequency of high
speed friction
torque
Flux weakening
integral gain
Flux-weakening
control mode
0x000–0x112
Ones place: Control mode
0: Mode 0
1: Mode 1
2: Mode 2
Tens place: Compensation of inductance saturation