Two-wire terminals
2.1.7.
Two-wire terminals
LINE-1 and LINE-2 terminals are used for the actual two-wire connection. Each terminal is equipped with a
switch for disconnecting the line during troubleshooting. For more information, turn to Section 3.1.7,
“Connecting the Two-wire” [14].
Warning
While the Ranger Converter 3000 is running, a short on the two-wire will not clear the display
and thus it might still display active stations even if they are not active.
2.1.8.
Master valve activation
Use this terminal to connect a push button which may turn on the master valve when activated. This enables
you to manually activate the master valve. When activated, the master valve will remain turned on for a
specified number of hours. Pressing the push button quickly, when the master valve is on, will restart the
timer. A longer push (more than 3 seconds) will stop the master valve. For more information, turn to
Section 3.1.3, “Connecting the Master Valve” [10].
2.1.9.
Flow input
Input is not used. Instead flow is read via one or two sensor decoders on the 2-wire. These sensor
decoders must have address 50000 and 50001 respectively.
2.1.10.
Decoder programming terminals
These terminals are used when programming decoders. All wires on the decoder must be connected. Blue
wires to the left, white wires to the right. Section 3.1.8, “Connecting Decoders for Programming[15].
2.1.11.
Remote activation
This feature is not implemented. Planned for a future release.
2.3. The Ranger Converter 3000 Extender
The Ranger Converter 3000 Extender is like the Ranger Converter 3000 Board itself but without the the
display and control panel. By adding the Ranger Converter 3000 Extender to your Ranger Converter 3000
system you may increase the capacity with up to another 48 stations and an additional master valve. The
master valve operates in parallel with the existing master valve input. The Ranger Converter 3000
Extender connects to the Ranger Converter 3000 system via the expansion terminal on the Ranger
Converter 3000 board.
For information on connecting the Ranger Converter 3000 Extender to the Ranger Converter 3000 Board,
turn to Section 3.1.9, “Connecting the Ranger Converter 3000 Extender to the Ranger Converter 3000
Board” [16].