EasyManuals Logo

Stanley NB08PT-18 User Manual

Stanley NB08PT-18
626 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
8.2 SETTING ASSESSMENT CRITERIA AVERAGE MODE *IN CASE OF SMART FUNCTION ON
NB08PT-18 PB2500Smart
Open “Smart Function menu from the
setting menu
Touch “Assessment”.
Not Available
Turn ON Average mode and Touch Average
mode”
(Blue: ON, Black: OFF)
Set 5 rivets you use to collect the riveting
data.
Cursor moves rightward every setting
automatically.
If you want/need to get new data, touch the
value of result you want to change and set a
rivet again.
After completing, touch “Criteria icon to set
the ranges for Stroke and Force.
Set the ranges for Stroke and Force. Touch
the range value you want to change with
Up-Down icons.
*Default settings: 20% each
Note, if you set the range to too small one, it
has a potential that NOK occurs frequently.
Reference measurement accuracies are as
follows.
Stroke: ±0.5mm
Force: ±500N~1,000N
After setting, touch “Back Home” icon.
Criteria icon
31
ENGLISH

Table of Contents

Other manuals for Stanley NB08PT-18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley NB08PT-18 and is the answer not in the manual?

Stanley NB08PT-18 Specifications

General IconGeneral
BrandStanley
ModelNB08PT-18
CategoryPower Tool
LanguageEnglish

Related product manuals