EasyManua.ls Logo

Stihl TS 420 - 8.6.2 Removal and installation

Stihl TS 420
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56 TS 410, TS 420
: Ensure that the machined key
(arrow) engages in the groove on
the crankshaft stub.
Check the air gap between
ignition module and flywheel,
adjust if necessary, b 8.1.1.
Reassemble remaining parts in
reverse order.
Tightening torques, b 3.5.
8.6 Short circuit wire/ switch
8.6.1 Testing
Check the short circuit wire if the
spark plug and ignition lead with
spark plug boot are in order.
Remove the fan cover, b 7.3.
: Disconnect the short circuit
wire (1).
370RA208 TG
1
370RA209 TG
Connect the ohmmeter to
ground (arrow) and the short
circuit wire (1).
Set the switch shaft to "
0".
The resistance measured must be
about 0 ohm. If it is much higher, the
reason is a break in the wire and the
switch must be replaced, b 8.6.2.
Set the switch shaft to "F".
The measured resistance must be
infinitely high, otherwise replace the
switch, b 8.6.2.
If no fault can be found, test the
ignition system in accordance with
flow chart, b 8.7.
Test the complete switch unit for
continuity.
Reassemble parts in reverse
order.
8.6.2 Removal and installation
The switch, short circuit wire and
ground wire form a single unit. The
complete switch must be replaced if
there is any sign of damage.
Remove the shroud, b 7.4.
Remove the fan cover, b 7.3.
: Remove the spark plug boot (1).
Pull the ignition lead out of the
cable guides (arrows).
: Disconnect the ground wire (1)
and short circuit wire (2).
370RA210 TG
1
370RA211 TG
1
2

Table of Contents