EasyManuals Logo

Stryker Prime Series User Manual

Stryker Prime Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
AAttttaacchhiinngg tthhee ssiiddeerraaiill ppaaddss
To attach the siderail pads:
1. Tuck the siderail pad between the mattress and the siderail.
2. Attach the hook and loop fastener straps around the top of the siderail to secure the siderail pad.
LLooccaattiinngg tthhee ppaattiieenntt rreessttrraaiinntt ssttrraapp ttiiee--iinnss
WWAARRNNIINNGG
Always use caution when you attach restraint straps. Patient or operator injury may occur. Physical restraints, even if
secured, may result in serious harm to patients and operators, including entanglement, entrapment, physical injury, or
death.
Always attach restraint straps or devices only at the identified attachment points of the product. Failure to do so may
result in patient or operator injury. Do not attach restraint straps to the siderail.
Always refer to the applicable state and federal restrictions and regulations and the appropriate facility protocols before
you use any restraint strap or device.
There are eight patient restraint strap tie-in locations on the litter assembly for attaching patient restraint straps (Figure 31
or Figure 32).
FFiigguurree 3311 PPrriimmee rreessttrraaiinntt ssttrraapp llooccaattiioonnss
FFiigguurree 3322 PPrriimmee XX ooppttiioonn rreessttrraaiinntt ssttrraapp llooccaattiioonnss
NNoottee -- Restraint straps are Type B applied parts.
PPoossiittiioonniinngg tthhee uupprriigghhtt XX--rraayy ccaasssseettttee hhoollddeerr,, PPrriimmee XX
WWAARRNNIINNGG
Always take protective measures when you use the upright or lateral X-ray cassette holder. The X-ray cassette holder
does not protect against radiation.
Always refer to local, state, and federal guidelines in addition to facility protocols for safety before you use PPrriimmee XX with
radiation generating devices. Radiation generating devices may produce residual, stray, or scattered radiation.
Always use extra caution when you use a mattress thicker than 2.5 in. or a mattress overlay with PPrriimmee XX.
Always follow the
Positioning the upright X-ray cassette holder - Prime X option
instructions to insert the X-ray cassette.
The X-ray cassette holder attaches to the Fowler backrest weldment to support X-ray cassettes. You can take X-rays while
a patient is on the product. You can also adjust the cassette’s position before you take an X-ray.
EN 50 1115-309-001 Rev AD.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stryker Prime Series and is the answer not in the manual?

Stryker Prime Series Specifications

General IconGeneral
ModelPrime Series
CategoryMedical Equipment
Power Requirements120V AC, 60Hz
Battery BackupYes
TypeMedical Bed
Weight Capacity500 lbs
Featuresintegrated scale
CompatibilityCompatible with Stryker