Chapter 6 Diagnostics 6-21
In addition to the information in CODE EXAMPLE 6-6, prtdiag with the verbose
option (-v) reports on front panel status, disk status, fan status, power supplies,
hardware revisions, and system temperatures.
CODE EXAMPLE 6-7 prtdiag Verbose Output
In the event of an overtemperature condition, prtdiag reports an error in the Status
column for that device.
CODE EXAMPLE 6-8 prtdiag Overtemperature Indication Output
Similarly, if there is a failure of a particular component, prtdiag reports a fault in
the appropriate Status column.
CODE EXAMPLE 6-9 prtdiag Fault Indication Output
System Temperatures (Celsius):
-------------------------------
Device Temperature Status
---------------------------------------
CPU0 59 OK
CPU2 64 OK
DBP0 22 OK
System Temperatures (Celsius):
-------------------------------
Device Temperature Status
---------------------------------------
CPU0 62 OK
CPU1 102 ERROR
Fan Status:
-----------
Bank RPM Status
---- ----- ------
CPU0 4166 [NO_FAULT]
CPU1 0000 [FAULT]