B-4 Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual • May 2006
B.4 Environmental Requirements
TABLE B-5 lists environmental requirements for the Sun Ultra 45 or Ultra 25
workstation.
B.5 Shock and Vibration Specifications
TABLE B-6 lists vibration specifications for the Sun Ultra 45 or Ultra 25 workstation.
TABLE B-5 Environmental Requirements
Specification Operating Nonoperating
Temperature 32 F to 104 F (0 C to 40 C) -40 to 158 F (-40 C to 70 C)
Humidity 10% to 90% RH noncondensing, 27 C
max wet bulb
93% RH noncondensing
Altitude 10,000 ft (~3 km) 40,000 ft (~12 km)
TABLE B-6 Shock and Vibration Values
Constraint Operating Nonoperating
Shock 5 G’s, 11 msec, half-sine 30 G’s, 11 msec, half-sine
Vibration 0.2 G’s, 5 to 500 Hz swept-sine 1.0 G’s, 5 to 500 Hz swept-sine
Handling
Drop
N/A 100 mm

Table of Contents