Ensure sufficient heat dissipation when
installing the solar inverter in a switch
cabinet or closed room.
The ambient temperature may not drop
below or exceed -25°C and +40°C respec
-
tively. At ambient temperatures above
40°C, the inverter automatically reduces
its output.
The solar inverter should not be exposed
to direct sunlight to protect it from un
-
necessary external warming.
Protection against moisture and foreign
bodies
The high protection type IP54 allows in
-
stallation indoors and in roof-covered ar
-
eas outdoors, however the solar inverter
may not be directly exposed to rain.
Requirements for installation location
300 mm
300 mm
300 mm
300 mm
Wall
Ceiling
Cold
air
Hot
air