Malfunction Description Remedies
303:Overtmp. Your solar inverter is designed
for an ambient temperature of
up to +40°C. When a specified
temperature threshold of the
heat sink is reached, the output
power is reduced linearly.
Should the heat sink tempera
-
ture nevertheless continue to
increase, feeding is stopped.
After the heat sink tempera
-
ture drops, the solar inverter
starts up again automatically.
The maximum permissible
ambient temperature has been
exceeded.
The installation location
is not suitable. Please find
another installation location.
The necessary air circulation
was not taken into account
during installation.
Clean the solar inverter, if
dirt prevents cooling.
Observe the installation
distances specified in the
manual.
Objects were laid on the heat
sink and unimpaired convec
-
tion was prevented.
Remove the objects.
84
Malfunction Description Remedies
304:Mains rel. The AT solar inverter checks the
operation of the mains relay
prior to every switch-on. An
error was detected during this
check.
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.
305:AFI Test The AT solar inverter checks the
operation of its residual-cur
-
rent monitoring unit prior to
every switch-on. An error was
detected during this check.
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.