91
Malfunction Description Remedies
406:Solar
(Warning)
No sensor found on sensor
channel 1 (solar).
If you have connected a sensor:
Check the connection to
your sensor.
If you have not connected a
sensor:
Check the conguration
with the Sunways Browser.
407:Temp.
(Warning)
No sensor found on sensor
channel 2 (temperature).
If you have connected a sensor:
Check the connection to
your sensor.
If you have not connected a
sensor:
Check the conguration
with the Sunways Browser.
Malfunction Description Remedies
408:CAN Comm
(Warning)
Communication malfunctions
occur repeatedly on the CAN
bus.
A malfunction occurs in the
data transmission on the CAN
bus.
However, a data exchange con
-
tinues to be possible.
Check whether all connec-
tors of the bus lines and the
terminating resistors are
properly mounted.
Check whether the bus lines
have been routed parallel to
power cables. Separate bus
lines and power cable from
each other spatially if neces
-
sary.
409:CAN Conf.
(Warning)
CAN bus is in the configuration
mode. No measured values are
transferred.
At least one unit is in the menu
item «Settings – Network
– CAN bus».
Close this menu for all units.