109
(6) The buzzer will emit four (4) long beeps, followed by two (2)
s
hort beeps emitted four times.
When you hear the two (2) short beeps, immediately
remove the lock plate from the stop switch, then reinstall it.
NOTE:
The buzzer emits short beeps, which indicate which key fob ID
code has been registered in the keyless control unit.
This pattern is repeated every five seconds until the yellow lead
wire and black lead wire are disconnected.
(7) Briefly press the lock button of the key-fob being added to
the keyless start system within ten (10) seconds of attach-
ing the lock plate to the emergency stop switch.
Buzzer sounding pattern
4 times
4 times
4 times
OFF
ON
Lock button
Red LED