6-24 ELECTRICAL SYSTEM
BATTERY
SPECIFICATIONS
1
Upper cover breather
5
Terminal
2
Cathode plates
6
Safety valve
3
Stopper
7
Anode plates
4
Filter
8
Separator (Fiberglass plate)
INITIAL CHARGING
Filling electrolyte
Remove the aluminum tape
1
sealing the battery electrolyte
filler holes
A
.
NOTE:
When filling electrolyte, the battery must be removed from the
vehicle and must be put on the level ground.
Remove the caps
2
.
NOTE:
* After filling the electrolyte completely, use the removed cap 2
as sealing caps of battery-filler holes.
* Do not remove or pierce the sealed areas 3 of the electrolyte
container.
Insert the nozzles of the electrolyte container
4
into the bat-
tery’s electrolyte filler holes, holding the container firmly so
that it does not fall. Take precaution not to allow any of the
fluid to spill.
Make sure air bubbles
5
are coming up in each electrolyte
container, and leave in this position for about more than 20
minutes.
Type designation YTX7A-BS
Capacity 12 V, 14.4 kC (6 Ah)/10 HR

Table of Contents